E-Dust Soiling Sensor
Special PV SystemEntec Solar

E-Dust Soiling Sensor

Every minute, the E-Dust compares the full I-V curves of two identical modules, one kept clean and one left to soil like the plant, and returns the soiling ratio at the maximum power point, as defined in IEC 61724-1.

Tests to
IEC 61724IEC 60904
Datasheet (PDF) ↗
Manufacturer:Entec Solar

Details

Specifications
Inputs2 PV modules, four-wire (clean and soiled)
Maximum input80 V · 25 A
Recommended at STCup to 65 V · 20 A per module
Accuracy±0.3 % V and I · ±0.5 % P
Resolution2.5 mV · 0.3 mA
Measurementone I-V curve per module per minute
TemperatureVoc method (IEC 60904-5); 2 × PT1000 optional
CommunicationModbus TCP or TCP/IP to PVET · RJ45
ProtectionIP67 and IP51 versions
Power12/24 V DC · 200 mA at 12 V
Size and weight215 (244) × 150 × 60 mm · 1.0 kg

Soiling is rarely uniform, and neither is the loss. Sensors that only compare short-circuit current see the light that does not arrive; the E-Dust measures the power that is not produced, which with uneven soiling can be much higher.

It works with two reference modules of the plant's own model: one is kept clean and the other soils like the rest of the array. Every minute it traces the full I-V curve of each one (150 points, four-wire connection) and calculates the soiling ratio, calibrated and temperature-compensated. The results go to the SCADA over Modbus TCP or directly to PVET Data Analytics, which shows daily, monthly and yearly losses and helps decide the best moment to clean.

Key features

  • Power, not just current: soiling ratio at the maximum power point (IEC 61724-1).
  • One curve per module, every minute: 150 points, four-wire, so cable resistance does not affect the measurement.
  • Temperature compensated: Voc method (IEC 60904-5) or two optional PT1000 probes.
  • Plant integration: Modbus TCP or TCP/IP to PVET Data Analytics, RJ45 Ethernet, 12/24 V DC.
  • Outdoors: installed on the structure next to its modules; IP67 and IP51 versions.

Request a quote

Quote for E-Dust Soiling Sensor

E-Dust Soiling SensorRequest a quote

More in Special PV System

Entec Solar

E-1500 Smart I-V Curve Tracer

The smallest, lightest and fastest I-V curve tracer on the market. Up to 200 curves per hour on modules and strings, bifacial included, with every curve translated to standard test conditions (STC) on the spot.

Request a quote
Entec Solar

E-Ref Datalogger for Reference PV Modules

The E-Ref measures the short-circuit current and open-circuit voltage of a reference module of the same type as the plant's, and delivers irradiance and cell temperature to the SCADA by Modbus, with no further conversion. Versions for monofacial and bifacial modules.

Request a quote
For rent

Seaward PV:1525-IV Solar PV Tester & I-V Curve Kit

Handheld tester for essential safety and commissioning tests on PV systems up to 1500 V DC and 25 A, with I-V curve tracing.

Request rental